Checking Program - Air Conditioning Frontera MY'94
| Test | Test Equipment | Test | Notes | Nominal | ||
|---|---|---|---|---|---|---|
| Step | Multimeter | |||||
| MKM-587-A | of | |||||
| between | ||||||
| Value: | ||||||
| 01 | Voltmeter range 20 V, DC | Voltage supply | K6 / ter. 8 | Ground | · Remove cut - off relay K60 from engine compartment fuse box |
· Remove compressor relay K6 from relay socket
· Engine running
· Engine off
| · Measurement at relay socket | > 11.5V | |
|---|---|---|
| 0 V | ||
| Troubleshooting | Nominal Value | Cause of Fault |
· Ignition "OFF"
· Remove blower relay K7 from engine compartment fuse box
· Measure resistance with multimeter
from: Compressor relay K6, relay socket ter. 8
to: Blower relay K7, relay socket ter. 3
| approx. 0 W | · Fuse F47 defective |
or
· Fuse F47E defective
or
· Line interrupted or short circuit to voltage
from: K6, relay socket ter. 8
| to: K7, relay socket ter. 3 |
· Measure voltage with multimeter
from: Blower relay K7, relay socket ter. 5
| to: Ground | > 11.5 V | · Main fuse F11E defective |
or
· Line interrupted
from: K7, relay socket ter. 5
to: Main fuse F11E
· Measure resistance with multimeter
from: Blower relay K7, relay socket ter. 2
to: Ground
| approx. 0 W | · Line interrupted |
from: K7, relay socket ter. 2
| to: Ground | |
|---|---|
| If nominal values are attained: | · Line interrupted |
from: Blower relay K7, relay socket ter. 1
to: Alternator G2
or
| · Blower relay K7 defective |