MATERIAL SPECIFICATIONS

ItemSpecificationFill Capacity
A/C Cooling Coil Coating YN-29
A/C System Flushing Solvent YN-23
PAG Refrigerant Compressor Oil (R-134a Systems) YN-12-DWSH-M1C231-BNon-hybrid 148 ml (5 fl. oz.) Hybrid 325 ml (11 fl. oz.)
R-134a Refrigerant YN-19 (US); CYN-16-P or CYN-16-R (Canada)WSH-M17B19-ANon-hybrid 0.71 kg (25 oz.) (1.57 lb) Hybrid 1.08 kg (38 oz.) (2.38 lb)

MATERIAL SPECIFICATIONS

GENERAL SPECIFICATIONS

ItemSpecification
A/C Compressor
A/C compressor typeDKS-17DS
RotationClockwise
A/C Compressor Magnetic Clutch
Air gap between pulley and hub0.3-0.6 mm (0.012-0.024 in)
A/C Low Charge Protection Switch - 2.3L, 3.0L (4V)
Close110-165 kPa (16-24 psi)
Open62-76 kPa (9-11 psi)
A/C Pressure Relief Valve
Open3,682 kPa (534 psi) minimum
Dual-Function Pressure Switch
A/C clutch cut-in (closed contacts)1,517-1,931 kPa (220-280 psi)
A/C clutch cut-out (open contacts)2,999-3,275 kPa (435-475 psi)
High speed fan ON (closed contacts)1,965-2,172 kPa (285-315 psi)
High speed fan OFF (open contacts)1,482-1,965 kPa (30-70 psi)
Front Thermistor
Cut-in/cut-out2.2°C (36°F)/0.6°C (33°F)

GENERAL SPECIFICATIONS

Note. The General Specifications apply to non-hybrid vehicles only. For hybrid General Specifications, refer to CLIMATE CONTROL SYSTEM - GENERAL INFORMATION AND DIAGNOSTICS - HYBRID .