MATERIAL SPECIFICATIONS

ItemSpecificationFill Capacity
PAG Refrigerant Compressor Oil (R-134a Systems) YN-12-DWSH-M1C231-B
R-134a Refrigerant YN-19 (US); CYN-16-P or CYN-16-R (Canada)WSH-M17B19-A

MATERIAL SPECIFICATIONS

TIGHTENING TORQUE SPECIFICATIONS

DescriptionNm
Auxiliary airflow mode door actuator screws2
Auxiliary climate control fresh air inlet duct nuts7
Auxiliary climate control housing bolts7
Auxiliary line dash panel bracket nut6
Auxiliary line floor pan bracket nuts6
Battery airflow duct screws2
Battery zone valve screws2
Battery zone valve tube-O fitting nuts17
Front auxiliary evaporator inlet line front fitting nut8
Front auxiliary evaporator outlet and inlet line bracket bolt6
Front auxiliary evaporator outlet and inlet line mid-joint fitting nuts8
Front auxiliary evaporator outlet line front fitting nut15
Rear auxiliary evaporator inlet line tube-O fitting10
Rear auxiliary evaporator outlet and inlet line front bracket bolt6
Rear auxiliary evaporator outlet and inlet line rear bracket bolt6
Rear auxiliary evaporator outlet and inlet line rear fitting nuts8
Rear auxiliary evaporator outlet line tube-O fitting37
Thermostatic Expansion Valve (TXV) stud11
TXV-to-lower bracket nut11
TXV-to-upper bracket bolts8

TIGHTENING TORQUE SPECIFICATIONS