(1) heater matrix
(2) additional heating (according to equipment)
(3) engine cooling radiator
(4) expansion chamber
(5) water inlet housing
(6) exhaust gas/water exchanger
(7) coolant outlet housing
| coolant circuit | data |
|---|---|
| total capacity of circuit | 8 litres |
| total capacity of circuit (version with additional heating) | 9 litres |
| radiator surface area | 21 dm2 |
| pressurisation | 1,4 bar |
| opening of thermostatic regulator | 83 °C |
| air conditioning cut-off | 115 °c or 30 bar in the cooling circuit |
| warning | 118 °C |
| temperature sensor | temperature: diesel injection, alert, air conditioning |
| connector colour | Green |
| fans | data |
|---|---|
| number x electrical power | 1 x 300 Watts |
| 1 x 460 Watts | |
| 1st gear | 97 °C or air conditioning in operation |
| 2nd speed | 101 °c or 17 bar in the cooling circuit |
| 3rd speed | 105 °C or air conditioning in operation |
| post-cooling | 6 minutes |