Identification
(1) coolant inlet manifold
(2) water pump cover
(3) thermostat
(4) coolant outlet housing
(5) coolant outlet housing
(6) coolant temperature sensor
Tightening torques
| reference | designation | pre-tighten | tightening torque |
|---|---|---|---|
| (7) | 2 hexagonal washer screws M8 X 125 - 30 | - | 2,0 daNm |
| (8) | 1 stud screw | 0,5 daNm (*) | 1,6 daNm (*) |
| (9) | 4 bolts H M7 X 100 - 20 | 0,5 daNm (*) | 1,6 daNm (*) |
| (10) | 1 M6 X 100 (**) nut | - | 0,7 daNm |
(*) according to tightening sequence: 1 to 5
(**) after assembling the timing cases
| reference | designation | pre-tighten | tightening torque |
|---|---|---|---|
| (14) | 2 bolts CHC M6 X 100 - 45 | - | 0,8 daNm |
| (12) | 1 bolts CHC M6 X 100 - 20 | - | 0,8 daNm |
| (13) | 2 studs | - | 1,0 daNm |
| (14) | 2 nuts M8 X 125 | 1,0 daNm (*) | 2,5 daNm (*) |
| (13) | 4 bolts H M8 X 125 - 70 | 1,0 daNm (*) | 2,5 daNm (*) |
| (16) | 2 bolts H M8 X 125 - 60 | 1,0 daNm (*) | 2,5 daNm (*) |
(*) according to tightening sequence: 1 to 5