Data
Cooling system
| engine | capacity (litres) |
|---|---|
| EW10 manual gearbox | 7 |
| EW10 automatic gearbox | 7,2 |
Coolant
- Coolant GLYSANTIN G33 or REVKOGEL 2000
- Degree of protection -35 °C
- Without interval
- Alert pressure: 1,4 bar, 118 °C
| engine | air conditioning cut-off |
|---|---|
| EW10 | 115 °C |
Expansion chamber
Cap pressure: 1 bar
Colour identification: orange
| engine | coolant level sensor |
|---|---|
| EW10 | no OK |
Thermostat
| engine | starts to open at |
|---|---|
| EW10 | 89 °C |
| engine | complete opening |
|---|---|
| EW10 | 101 °C |
Engine cooling fans
| engine | power (W) |
|---|---|
| EW10 manual gearbox | 350 |
| EW10 automatic gearbox | 460 |
| - | engagement temperature |
|---|---|
| slow speed | 97 °c or 10 bar in the cooling circuit |
| mid speed | 101 °c or 17 bar in the cooling circuit |
| high speed | 105 °c or 22 bar in the cooling circuit |
| post ventilation | for 6 minutes beyond 105°C |
Radiator
25 dm2 surface
Aluminium harness
Polyamide coolant chambers
Without drain screw
Unit identification
Manual gearbox
(A) radiator
(B) expansion chamber
(B') screw cap pressure negative pressure
(C) coolant/oil heat exchanger (engine)
(D) coolant inlet manifold (coolant pump)
(E) heater matrix
(F) coolant outlet housing (thermostat)
(H) bleed screw(s)
Coolant pipes
- (1) radiator inlet
- (2) radiator degassing
- (3) venting chamber inlet
- (4) venting chamber outlet towards engine
- (5) engine oil/coolant heat exchanger inlet
- (6) engine oil/coolant heat exchanger outlet
- (7) radiator outlet
- (8) coolant outlet housing pipe towards coolant pump
- (9) "by-pass" coolant outlet housing
- (10) heater matrix outlet
- (11) heater matrix inlet
Automatic gearbox
(G) coolant/oil heat exchanger
Coolant pipes
- (12) automatic gearbox oil/coolant exchanger inlet
- (13) automatic gearbox oil/coolant exchanger outlet