- Press --> button.
Indicated on display
Scheme 26
The change over valve in the LDP is activated for approximately 1 minute (clicks), unless the button pressed to switch to the next actuator.
Note. The clicking can be heard by listening in the area of the left rear wheel housing.
If valve is not actuated (does not click), see EVAPORATIVE EMISSIONS (EVAP) SYSTEM, SERVICING .