Home/Volvo/C70/Volvo C70 I (1997-2005)/Repair manual/Passive Restraints/Restraints - Specifications, Electrical/electronic (Convert…
Contents Wiring diagrams Section: Passive Restraints All sections

Restraints - Specifications, Electrical/electronic (Convertible): Other Volvo C70 I

Activating components/functions

Activate Volvo Scan Tool (ST) components/functions by pressing the YES/NO key or ENTER key to initiate the relevant function.

NumberComponent/functionFunction
1RESET KONTROLLRestarts the control module (corresponds to switching the ignition off/on).
2S A TT TRANSP.S A KRSets the transit safety device to active mode.
3AVAKTI.TR.S A KRDeactivates the transit safety device.
4NOLLST.S A KB.R AResets the counter that records the number of times the roll-over bars have been deployed. May only be reset after the roll-over bars have been replaced. A password is required.
5AKTIVERA.S A KB.Activates the roll-over bars. Password required.

ROPS activation table

NumberComponent / functionFunction
1RESET KONTROLLRestarts the control module (corresponds to switching the ignition off/on).

SRS activation table

Activating ROPS components / functions

Activate components / functions by clicking the VCT 2000 symbol.

NoComponent / functionFunction
1Activating the resetting checkRestarts the control module (corresponds to switching the ignition off/on).
2Set transport modeSets the transit safety device to active mode.
3Set transport modeDeactivates the transit safety device.
4Reset the trigger counterResets the counter that records the number of times the roll-over bars have been deployed. May only be reset after the roll-over bars have been replaced. A password is required.
5Activate the roll-over barActivates the roll-over bars. Password required.

ROPS activation table

Reading off parameters, ROPS

No.TextRemarks
1SYST.T daysTotal time the system has been active.
2UBAT VBattery voltage. Measurement range 0-15V.
3ENG.RESERVE VEnergy reserve that can deploy the roll-over bars 5 seconds after power supply is cut off.
4D+ VGenerator voltage. Measurement range 0-15V.
5AB.DTC.S daysAbsolute DTC start.
6AB.DTC.E daysAbsolute DTC end.
7RE.DTC.S hr/min/secRelative DTC start. Last ignition switch on.
8RE.DTC.E hr/min/secRelative DTC end. Last ignition switch on.
9COUNTER 1Diagnostic Trouble Code (DTC) status INT=0, PERM>0.
10COUNTER 2Counts upwards each time a fault occurs and disappears. Maximum 255 times.
11READ TRANSIT SAFETYReads off whether or not the transit safety catch is set.
12READ.NO.DEPLReads the number of times the roll-over bar has been deployed.

ROPS Parameter table

Control module

Operating current9-16 V, type 13.5 V
Wait position<=9 0.5 V (leaves wait position at >10 V)
SRS indicator lamp on<=9 0.5 V (low voltage warning)
Polarity shield>= -16 V constantly
Over charging18 V for 2 hours
Jump start24 V max 1 minute
Start-up time<= 3.5 - 6.5 s, type 5 s for full function