Home/Volvo/C70/Volvo C70 I (1997-2005)/Repair manual/Cooling System (Mechanical)/Engine - Cooling, Ignition & Control Systems - Specificatio…
Contents Wiring diagrams Section: Cooling System (Mechanical) All sections

Engine - Cooling, Ignition & Control Systems - Specifications, Removal & Installation (Convertible): Specifications Volvo C70 I

Cooling System (Mechanical) 2 illustrations ~264 words

Outer temperature sensor Specifications

Temperature, °CResistance, ohmsVoltage, V
063183.99
1038573.53
2024243.01
3015132.43
4010341.96

Outside temperature sensor Specifications

Temperature, °CResistance, ohmsVoltage, V
014072.34
10912.81.82
20607.51.38
255001.19
30413.81.03

Outside temperature sensor

Scheme 108

Scheme 108: Removing ignition coils

Remove

  1. the charge air pipe over the engine. Seal the openings

Scheme 109

Scheme 109
  1. the upper timing belt cover
  2. the cover over the ignition coils Disconnect the ignition coil connector.
  3. the mounting screw. Pull the coil up.

Signal specification (C70)

C70

  1. For 5 cylinder turbocharged engines -2002, see «Signal specification»(ref-403971-S16906518782011061000000)
  2. For 5 cylinder turbocharged engines 2003-, see «Signal specification»(ref-403971-S08137914272011061000000).

Signal specification (S80 & XC90)

S80

  1. For 6 cylinder engines -2001, see «Signal specification»(/volvo/c70/i-1997-2005/remont/engine-control-systems/#control-module-signal-specifications-convertible__signal-specification-s80-6-cylinder-engines)
  2. For 6 cylinder engines 2002-, see «Signal specification»(/volvo/c70/i-1997-2005/remont/engine-control-systems/#control-module-signal-specifications-convertible__signal-specification-s80-6-cylinder-engines)
  3. For 6 cylinder engines -2004, see «Signal specification»(/volvo/c70/i-1997-2005/remont/engine-control-systems/#control-module-signal-specifications-convertible__signal-specification-s80-6-cylinder-engines)
  4. For 6 cylinder engines 2005-, see «Signal specification»(/volvo/c70/i-1997-2005/remont/engine-control-systems/#control-module-signal-specifications-convertible__signal-specification-s80-xc90-6) .

XC90

  1. For 6 cylinder engines -2004, see «Signal specification»(ref-438318-S17763914152011120100000)
  2. For 6 cylinder engines 2005-, see «Signal specification»(/volvo/c70/i-1997-2005/remont/engine-control-systems/#control-module-signal-specifications-convertible__signal-specification-s80-xc90-6) .

Signal specification (XC90 - 6 cylinder engines -2004)

General

All values listed below should be measured between the respective terminal in column 1 (control module terminal) and terminal #B3 unless stated otherwise in column 6 (Other). Control module terminals #A1-#A70 correspond to terminals #A1-#B10 on the breakout box, terminals #B1-#B50 correspond to #B11 - #B60 on the breakout box.

Note. It is important to connect the breakout box and check the ground terminals before taking readings.

HINT: If the numbering of the connector is different from the numbering on the breakout box, the connector number is given first, terminal #A61, followed by the breakout box number in brackets, (#B1). Example: #A61 (#B1).

U=DC voltage in volts (V)U AC =AC voltage in volts (V)
U bat =Battery voltage (V)F =Frequency in Hertz (Hz)
U low =Voltage approximately 0 V% duty =Duty cycle (pulse ratio) as a percentage (%)
T =Time in milliseconds (ms)I =Current in amperes (A)
Control module terminalBreakout box terminalSignal typeIgnition onEngine idlingOther
#A1#A1Throttle unit signal, potentiometer 1 (circuit 1)U approx. 0.4 -4 VThe voltage varies depending on the position of the throttle. U increases with throttle opening.
#A2#A2
#A3#A3
#A4#A4Engine coolant temperature (ECT) sensor signal(+30°C) U=1.22 V (+80°C) U = 0.29 V (+100°C) U = 0.17 V
#A5#A5Intake air temperature (IAT) sensor signal(+20°C) U = 3.50 V (+30°C) U = 3.00 V (+40°C) U = 2.50 VThe intake air temperature (IAT) sensor is integrated in the boost pressure sensor.
#A6#A6Control signal, rear heated oxygen sensor (HO2S) preheatingU = UbatPreheating off: U = U bat Preheating on U=U low
#A7#A7Engine cooling fan (FC) control signalPulse width modulation (PWM) signal U high at least 70% of U bat U low =1.2V f = 100 Hz Pulse ratio = 10-95%
#A8#A8
#A9#A9Control signal, canister purge (CP) valveU = U batPWM signal during activation of the canister purge (CP) valve
#A10#A10
#A11#A11
#A12#A12
#A13#A13Control signal, intake camshaft reset valvePWM signal U top =U bat f=250Hz (12.5 Hz) Pulse ratio 20-95%The pulse ratio governs control of the camshaft
#A14#A14Injector no. 6 control signalU = U batT= 2-3 msT increases with engine speed (RPM) and load
#A15#A15Injector no. 2 control signalU = U batT= 2-3 msT increases with engine speed (RPM) and load
#A16#A16Injector no. 1 control signalU = U batT= 2-3 msT increases with engine speed (RPM) and load
#A17#A17Power supplyU = U batMeasured via the system relay
#A18#A18Control signal, preheating, bank 1, front heated oxygen sensor (HO2S)U = U batPreheating off: U = U bat Preheating on: U=U low
#A19#A19Signal ground, throttle unit, potentiometers 1 and 2U=U low
#A20#A20Throttle unit signal, potentiometer 2 (circuit 2)U approx. 4 -0.4 VThe voltage varies depending on the position of the throttle. U decreases with increasing throttle opening
#A21#A21Exhaust camshaft reset valve control signalPulse width modulation (PWM) signal U top =U bat f=250 Hz (12.5 Hz) Pulse ratio 20-95%The pulse ratio governs control of the camshaft
#A22#A22Mass air flow (MAF) sensor signalU = 1 VU = 1.7 VU increases with increasing air mass
#A23#A23Boost pressure sensor signalU = 1.96 VU increases with increasing boost pressure
#A24#A24Front heated oxygen sensor (HO2S), bank 1, pump currentPulsed current supply, not measured
#A25#A25Front heated oxygen sensor (HO2S), bank 2, pump currentPulsed current supply, not measured
#A26#A26Oil pressure switch signalU=U lowU = U bat
#A27#A27Signal camshaft position (CMP) sensor 2, exhaust camshaftU =5 VU = Pulsed signal U top =5 V Uoffset=2.5VThe frequency varies according to engine speed (RPM)
#A28#A28Front heated oxygen sensor (HO2S), bank 1, calibration currentNot measured
#A29#A29Power supply, 5 V camshaft position (CMP) sensorU =5 V
#A30#A30Ignition coil no. 5 control signalU=U lowU=2.5 V t high =2 msThe frequency varies according to engine speed (RPM)
#A31#A31Ignition coil no. 1 control signalU=U lowU=2.5 V t high =2.5 msThe frequency varies according to engine speed (RPM)
#A32#A32Injector no. 4 control signalU = U batT low =2-3 msT increases with engine speed (RPM) and load
#A33#A33Injector no. 3 control signalU = U batT low =2-3 msT increases with engine speed (RPM) and load
#A34#A34Injector no. 5 control signalU = U batT low =2-3 msT increases with engine speed (RPM) and load
#A35#A35Control signal (+) damper motor for the throttle unitPulse width modulation (PWM) signal U top =U bat Pulse ratio 0-100%. The polarity of the control signal changes when the damper motor is deployed against the direction of rotation.The damper motor is controlled from the integrated power stage in the engine control module (ECM) measured to terminal #A36 (#A36)
#A36#A36Control signal (-) damper motor for the throttle unitPulse width modulation (PWM) signal U top =U bat Pulse ratio 0-100%. The polarity of the control signal changes when the damper motor is deployed against the direction of rotation.The damper motor is controlled from the integrated power stage in the engine control module (ECM) measured to terminal #A35 (#A35)
#A37#A37
#A38#A38Turbocharger (TC) control valve control signalU = U batDuring turbocharger (TC) control: Pulse width modulation (PWM) signal f = 32 Hz
#A39#A39Power supply 5 V boost pressure sensor, air conditioning (A/C) pressure sensor, mass air flow (MAF) sensorU =5 V
#A40#A40
#A41#A41Signal (+), front heated oxygen sensor (HO2S) bank 1Pulsed current signal, not measured
#A42#A42Signal (-), front heated oxygen sensor (HO2S) bank 1Pulsed current signal, not measured
#A43#A43Signal (+), front heated oxygen sensor (HO2S) bank 2Pulsed current signal, not measured
#A44#A44Signal (-), front heated oxygen sensor (HO2S) bank 2Pulsed current signal, not measured
#A45#A45Signal (+), rear knock sensor (KS)U=U low
#A46#A46Signal (+) front knock sensor (KS)U=U low
#A47#A47Signal camshaft position (CMP) sensor 1, intake camshaftU =5 VU = Pulsed signal U top =5 V U offset = 2.5 VThe frequency varies according to engine speed (RPM)
#A48#A48Signal (+), flywheel sensorU=2.5 VU= sine wave voltage U top =5 V U offset = 2.5 VMeasured to terminal #A66 #B6) The frequency increases with engine speed (RPM)
#A49#A49Ignition coil no. 4 control signalU=U lowU=2.5 V t high =2 msThe frequency varies according to engine speed (RPM)
#A50#A50Ignition coil no. 2 control signalU=U lowU=2.5 V t high =2 msThe frequency varies according to engine speed (RPM)
#A51#A51Ignition coil no. 6 control signalU=U lowU=2.5 V t high =2 msThe frequency varies according to engine speed (RPM)
#A52#A52Ignition coil no. 3 control signalU=U lowU=2.5 V t high =2 msThe frequency varies according to engine speed (RPM)
#A53#A53Power ground 3U lowGround terminal connected to the chassis
#A54#A54Power ground 2U lowGround terminal connected to the chassis
#A55#A55
#A56#A56
#A57#A57
#A58#A58Signal ground, mass air flow (MAF) sensorU=U low
#A59#A59Power supply 5 V throttle unit, potentiometers 1 and 2U =5 V
#A60#A60Signal ground Air conditioning (A/C) pressure sensor, boost pressure sensor, engine coolant temperature (ECT) sensorU=U low
#A61#B1Signal (+), rear heated oxygen sensor (HO2S)Uapprox.0.50 VAbove 0.6 V or below 0.3 V
#A62#B2Signal (-), rear heated oxygen sensor (HO2S)U=U lowU=U low
#A63#B3Signal groundU=U lowGround terminal connected to the chassis
#A64#B4Signal (-) front knock sensor (KS)U=U lowU=U low
#A65#B5Camshaft position (CMP) sensor signal groundU=U low
#A66#B6Signal (-) flywheel sensorU=2.5 VU = sine wave voltage U top =5 V U offset = 2.5 VMeasured to terminal #A48 (#A48) The frequency increases with engine speed (RPM)
#A67#B7Signal (-) rear knock sensor (KS)U=U low
#A68#B8Air conditioning (A/C) pressure sensor signalU=0.9 V (at 20°C)U increases with pressure in the air conditioning (A/C) system
#A69#B9Front heated oxygen sensor (HO2S), bank 2, calibration currentNot measured
#A70#B10Control signal, preheating, bank 2, front heated oxygen sensor (HO2S)U = U batPreheating off: U = U bat Preheating on: U=U low
Control module terminalBreakout box terminalSignal typeIgnition onEngine idlingOther
#B1#B11Control modules communication cable (CAN L)
#B2#B12
#B3#B13
#B4#B14Signal ground, clutch pedal position sensor, outside temperature sensorU=U low
#B5#B15Signal ground, accelerator pedal (AP) position sensorU=U low
#B6#B16
#B7#B17Control signal, leak diagnostic unit, pumpPump motor running: U=U low Pump motor not running: U = U bat
#B8#B18Signal, coolant level sensorU=U lowLow engine coolant level: U = U bat Normal engine coolant level: U=U low
#B9#B19Power supply, 5 V accelerator pedal (AP) position sensorU =5 V
#B10#B20
#B11#B2130-supply (Power supply from the battery)U = U batU = U batIgnition off: U = U bat
#B12#B22
#B13#B23Control module communication cable (CAN H)
#B14#B24
#B15#B25Clutch pedal sensor signalUnaffected: U=3.3 V Fully depressed: 100 mm U=2.2 VU varies depending on the position of the clutch pedal
#B16#B26
#B17#B27Signal, accelerator pedal (AP) position sensorUnaffected: Uapprox.0.4 V Fully depressed accelerator pedal (AP): Uapprox.4 VU varies depending on the position of the accelerator pedal (AP)
#B18#B28
#B19#B29
#B20#B30
#B21#B31
#B22#B32Diagnostic lead C-linkU=90% of U batOther values apply if a generic fault-tracing instrument is connected to the data link connector (DLC)
#B23#B33Signal crank, 50-supplyU=U lowU=U lowAt crank: U = U bat
#B24#B34
#B25#B35Signal, accelerator pedal (AP) position sensorPulse width modulation (PWM) signal U top =U bat t=5 ms pulse ratio = 8-88%Pulse width modulation (PWM) signal from the accelerator pedal (AP) position sensor to the engine control module (ECM)
#B26#B36Stop lamp switch signalWhen the brake pedal is depressed: U = U bat When the brake pedal is not depressed U=U low
#B27#B37
#B28#B38
#B29#B39Signal, outside temperature sensor(0° C) U=2.92 V (+10° C) U=2.40V (+20° C) U=1.90 V (+30°C) U = 1.46 VTemperature range: -40 to +30°C
#B30#B40
#B31#B41
#B32#B42
#B33#B43
#B34#B44
#B35#B45
#B36#B46
#B37#B47Signal, ignition on, 15-supplyU = U batU = U batIgnition off: U=U low
#B38#B48System relay, control signalU=U lowRelay activated: U=U low Relay not activated: U = U bat The system relay runs on (2-5 minutes)
#B39#B49
#B40#B50Control signal, leak diagnostic unit, valveValve activated: U = Ulow Valve not activated: U = Ubat
#B41#B51
#B42#B52
#B43#B53
#B44#B54Control signal, air conditioning (A/C) relayAir conditioning (A/C) relay activated: U=U low Air conditioning (A/C) relay not activated: U = U bat
#B45#B55Fuel pump (FP) activation control signalPulse width modulated (PWM) signal to the central electronic module (CEM) to control the fuel pump (FP) relay
#B46#B56Malfunction indicator lamp (MIL) control signalU=U lowNot activated: U = U bat Activated: U=U low
#B47#B57
#B48#B58Control signal, engine cooling fan (FC), control modulesNot activated: U = U bat Activated: U=U lowThe engine cooling fan (FC) is controlled by the engine control module (ECM)
#B49#B59
#B50#B60