Home/Peugeot/Expert/Peugeot Expert I (1995-2006)/Repair manual/Power unit/Check: no. 1 - 4 injector control function
Contents Wiring diagrams Section: Power unit All sections

Check: no. 1 - 4 injector control function Peugeot Expert I

ECU information available

Actuator test: yes

Measure parameters: yes

Characterised by

  • Short circuit to positive
  • Open circuit or short circuit to earth
  • Not specified (short circuit to earth or short circuit to positive or open circuit)

Checks to be carried out if fault is present

Short circuit to positive

conditions under which the fault appearschecks to be made conditions for checking
engine runningverify: ignition on, ECU connected: - no voltage at terminal(s) 2 of the control unit 1320 (55V.NR) warning: presence of voltage, for 2/3 seconds after the ignition has been switched on ignition on, ECU connected, injector(s) 1/4 disconnected: - 12 V absent on terminal 2 of connector 55V.NR warning: if 12 V is present for 2/3 seconds after switching on the ignition, short circuit with a function supplied by +ve after relay

Open circuit or short circuit to earth

conditions under which the fault appearschecks to be made conditions for checking
engine runningverify: ignition off, control unit disconnected, injectors 1/4 connected, double relay disconnected: - no earth at terminal 2 on the 55V.NR connector - check continuity of wires A, B, E, F, G - resistance R of the injectors 1/4: 13 Ω ≤ R ≤ 16 Ω

Not specified (short circuit to earth or short circuit to positive or open circuit)

conditions under which the fault appearschecks to be made conditions for checking
engine runningverify: ignition on, ECU connected: - no voltage at terminal(s) 2 of connector 55V.NR warning: presence of voltage, for 2/3 seconds after the ignition has been switched on ignition on, ECU connected, injector(s) 1/4 disconnected: - 12 V absent on terminal 2 of connector 55V.NR warning: if 12 V is present for 2/3 seconds after switching on the ignition, short circuit with a function supplied by +ve after relay ignition off, control unit disconnected, injectors 1/4 connected, double relay disconnected: - no earth at terminal 2 on the 55V.NR connector - check continuity of wires A, B, E, F, G - resistance R of the injectors 1/4: 13 Ω ≤ R ≤ 16 Ω

Check(s) to be carried out if no fault found

Check that the injector is not physically sticking (actuator test)

+P: permanent +