Contents Wiring diagrams Section: Power unit All sections

Check: function double relay control Peugeot Expert I

ECU information available

Actuator test: yes

Measure parameters: no OK

Characterised by

  • Short circuit to positive
  • Open circuit or short circuit to earth

Checks to be carried out if fault is present

Short circuit to positive

conditions under which the fault appearschecks to be made conditions for checking
cutting off the ECU supply (for the double relay) with no ECU commandcontrol unit disconnected, ignition off, verify: - - condition and operation of double relay 1304

Open circuit or short circuit to earth

conditions under which the fault appearschecks to be made conditions for checking
cutting off the ECU supply (for the double relay) for more than 2 seconds, following the ECU commandcontrol unit disconnected, ignition off, verify: - - condition and operation of double relay 1304

+ P: permanent +