Contents Wiring diagrams Section: Power unit All sections

Check: injector control function Peugeot Expert I

ECU information available

Actuator test: yes

Measure parameters: yes

Characterised by

  • Open circuit
  • Short circuit to earth
  • Short circuit to positive

Checks to be carried out if fault is present

Open circuit

conditions under which the fault appearschecks to be made conditions for checking
engine running, open circuit (on terminal 17 of the ECU)verify: ECU connected, ignition on: - presence of 12 V at terminal 17 on control unit (on connecting each injector separately, one after the other) disconnect the injectors: - 14 Ω ≤ R ≤ 18 Ω at the terminals of each injector

Short circuit to earth

conditions under which the fault appearschecks to be made conditions for checking
engine running short circuit to earth (on terminal 17 of the ECU)verify: ECU connected, ignition on: - presence of 12 V at terminal 17 on control unit

Short circuit to positive

conditions under which the fault appearschecks to be made conditions for checking
engine running short circuit to positive (on terminal 17 of the ECU)verify: control unit disconnected, ignition on: - presence of 0 V at terminal 17 on control unit disconnect the injectors: - 14 Ω ≤ R ≤ 18 Ω at the terminals of each injector

Check(s) to be carried out if no fault found

Injector(s) disconnected, ignition on, verify: 12 V present at terminals 1 and 2 of connector 2 V.NR (for each injector)

Disconnect the injectors, verify: 14 Ω ≤ R ≤ 18 Ω at the terminals of each injector

Consistency of the signal detected by the ECU (measure parameters)