Home/Opel/GT/Opel GT II (2007-2009)/Repair manual/Engine Electrical/Electrical Power Management Description and Operation
Contents Section: Engine Electrical All sections

Electrical Power Management Description and Operation Opel GT II

Engine Electrical ~159 words

Electrical Power Management Description and Operation

Electrical Power Management

The electrical power management (EPM) is used to monitor and control the charging system and alert the driver of possible problems within the charging system. The EPM system makes the most efficient use of the generator output, improves the battery state-of-charge (SOC), extends battery life, and manages system electrical loads.

The load shed operation is a means of reducing electrical loads during a low voltage or low battery SOC condition.

The idle boost operation is a means of improving generator performance during a low voltage or low battery SOC condition.

Each EPM function, either idle boost or load-shed, is discrete. No 2 functions are active at the same time. Idle boost is activated in incremental steps, idle boost 1 must be active before idle boost 2 can be active. The criteria used by the body control module (BCM) to regulate EPM are outlined below:

FunctionBattery Temperature CalculationBattery Voltage CalculationAmp-hour CalculationAction Taken
Idle Boost 1 StartLess Than -15°C (+5°F)Less Than 13 V--First level idle boost requested
Idle Boost 1 Start----Battery has a net loss greater than 0.6 AHFirst level idle boost requested
Idle Boost 1 Start--Less Than 10.9 V--First level idle boost requested
Idle Boost 1 EndGreater Than -15°C (+5°F)Greater Than 12 VBattery has a net loss less than 0.2 AHFirst level idle boost request cancelled
Load Shed 1 Start----Battery has a net loss of 4 AHRear defrost, heated mirrors, heated seats cycled OFF for 20% of their cycle
Load Shed 1 Start--Less Than 10.9 V--Rear defrost, heated mirrors, heated seats cycled OFF for 20% of their cycle
Load Shed 1 End--Greater Than 12 VBattery has a net loss of less than 2 AHClear Load Shed 1
Idle Boost 2 Start----Battery has a net loss greater than 1.6 AHSecond level idle boost requested
Idle Boost 2 Start--Less Than 10.9 V--Second level idle boost requested
Idle Boost 2 End--Greater Than 12 VBattery has a net loss less than 0.8 AHSecond level idle boost request cancelled
Idle Boost 3 Start----Battery has a net loss of 10 AHThird level idle boost requested
Idle Boost 3 Start--Less Than 10.9 V--Third level idle boost requested
Idle Boost 3 End--Greater Than 12 VBattery has a net loss of less than 6 AHThird level idle boost request cancelled
Load Shed 2 Start--Less Than 10.9 VBattery has a net loss greater than 12 AHRear defrost, heated mirrors, heated seats cycled OFF for 50% of their cycle. The BATTERY SAVER ACTIVE message will be displayed on the DIC.
Load Shed 2 Start--Less Than 10.9 V--Rear defrost, heated mirrors, heated seats cycled OFF for 50% of their cycle. The BATTERY SAVER ACTIVE message will be displayed on the DIC.
Load Shed 2 End--Greater Than 12.6 VBattery has a net loss of less than 10.5 AHClear Load Shed 2
Load Shed 3 Start--Less Than 11.9 VBattery has a net loss greater than 20 AHRear defrost, heated mirrors, heated seats cycled OFF for 100% of their cycle. The BATTERY SAVER ACTIVE message will be displayed on the DIC.
Load Shed 3 End--Greater Than 12.6 VBattery has a net loss of less than 15 AHClear Load Shed 3