High-blower Relay Replace
Remove
- Disconnect the negative battery cable.
- The relay is located in front of the blower motor.
- Remove the glove box lower panel cover. Refer to Instrument Compartment Replace .
- Separate the relay from the connector.
- Remove the screw with the high-blower relay.
Install
- Install the screw with the high blower relay.
- Connect the electrical connector.
- Install the glove box lower panel cover. Refer to Instrument Compartment Replace .
- Connect the negative battery terminal.