Scheme 67
Operation check table
BLOWER MOTOR SPEED OUTPUT CONDITION CHART Step Device and operation Operation condition Monitor display (1) Other output condition 1 Blower motor speed 1 Air mix door opening angle 50% Airflow mode VENT A/C compressor ON (OFF when the blower is OFF) Air intake mode FRESH 2 Air mix door opening angle 20.5 Blower fan 2nd Airflow mode VENT A/C compressor ON Air intake mode FRESH 20.5 21.0 20.5 3 Airflow mode door switching 3 Blower fan 2nd Air mix door opening angle 50% A/C compressor ON Air intake mode FRESH 4 Air intake door switching 4 Blower fan 2nd Air mix door opening angle 0% Airflow mode VENT NOTE: A/C compressor ON/OFF can be verified "A/C" display on the information display. A/C compressor ON/OFF (1) Shown on the information display (at the set temperature display) according to the step