Contents Section: Automatic HVAC System All sections

General Information (HVAC): Other Kia Optima II рестайлинг

BLOWER UNIT

ItemSpecification
Fresh and recirculationOperating methodActuator
BlowerTypeSirocco
Speed stepAuto + 8 speed (Automatic) 1~8 speed (Manual)
Speed controlPower mosfet
Air filterTypeParticle filter

BLOWER UNIT SPECIFICATION

HEATER AND EVAPORATOR UNIT

ItemSpecification
HeaterTypePin & Tube type
Heating capacity4300 ± 5% kcal/hr
Mode operating methodActuator
Temperature operating methodActuator
EvaporatorTemperature control typeEvaporator temperature sensor
A/C ON/OFF [°C(°F)]ON : 2.1 ± 0.3 (41 ± 32.9) OFF: 0.6 ± 0.3 (33.08 ± 32.9)

HEATER AND EVAPORATOR UNIT SPECIFICATION