Contents Section: Automatic HVAC System All sections

General Information (HVAC): Specifications Kia Optima II рестайлинг

SPECIFICATION

ItemSpecification
2.0L2.4L2.7L
CompressorTypeVS
Oil type & CapacityPAG 150 ± 10cc
Pulley type6PK-TYPE
Displacement180cc/rev
CondenserHeat rejection14800 - 5% kcal/hr
APTThe method to measure the pressureVoltage = 0.00878835 * Pressure + 0.37081095
(A/C pressure transducer)
Expansion valveTypeBlock
RefrigerantTypeR-134a
Capacity [oz.(g)]17.6 ± 0.88 (500 ± 25)

SPECIFICATION CHART