Contents Wiring diagrams Section: Testing & Diagnostics All sections

P2610 (3) Chevrolet Uplander I

  1. The control module illuminates the MIL on the second consecutive ignition cycle that the diagnostic runs and fails.
  2. The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
  3. If the diagnostic reports a failure, the control module uses a cold start model based on the engine coolant temperature and intake air temperature at engine start-up. Using the cold start model ensures that the control module is able to determine how much time has elapsed between ignition cycles.