Home/Volvo/S80/Volvo S80 I (1998-2003)/Repair manual/Automatic HVAC System/Climate Control Module (Ccm) - Specifications & Communicati…
Contents Wiring diagrams Section: Automatic HVAC System All sections

Climate Control Module (Ccm) - Specifications & Communication: Other Volvo S80 I

Automatic HVAC System ~3870 words

Sun intensity, value (Electronic climate control)

Measurement range: 0 - 1000 W/m 2

The climate control module (CCM) calculates the sun intensity based on the signal from the sun sensor.

The value is used as a compensation parameter to control the passenger compartment temperature.

Evaporator temperature, value (Electronic climate control, Manual climate control)

Measurement range: -40 - 85°C

The climate control module (CCM) calculates the temperature based on the signal from the evaporator temperature sensor.

The value is used to control the air conditioning (A/C) compressor.

In normal operation (engine running and A/C selected) the control module can regulate the compressor in the following way

  1. 10°C air conditioning (A/C) compressor on
  2. 6.5°C air conditioning (A/C) compressor off.

At temperatures below 6°C the compressor is not permitted to operate because of the risk of freezing.

Twilight intensity, value

Measurement range: 0 - 15

The climate control module (CCM) calculates the twilight intensity based on the signal from the twilight sensor.

This value is transmitted to the central electronic module (CEM) via the control area network (CAN) to regulate the luminance of the buttons and combined instrument panel (DIM).

The value increases with increased and falls with diminished light intensity. The luminance of the buttons and combined instrument panel (DIM) will increase with increasing light intensity and fall with diminishing light intensity.

Power supply, delayed X-supply, value

Measurement range: 0 - 18 V

Normal value when the generator (GEN) is charging: 13.0 - 14.5 V

The value indicates the voltage at the climate control module (CCM). Delayed X-supply means that the power supply is maintained for 1 minute after the ignition is switched off. This is so that functions such as blower fan run-on and damper motor self-adjustment can be activated.

Matrix voltage, value

Incorrect f=165 50 Hz

Measurement range: 0 - 5 V

Matrix voltage means that the climate control module (CCM) supplies the damper motors with an impulse sequence via four common cables (connected in parallel). The impulse sequence consists of power supply and signal ground. This determines which direction the damper motors should move when activated. There is also a separate cable from the climate control module (CCM) to each damper motor. This cable controls the number of stages each damper motor should be moved based on the signal from the climate control module (CCM).

Cabin temperature (ECC)

Measurement range: -40 - 85°C

The climate control module (CCM) calculates the temperature based on the signal from the passenger compartment temperature sensor.

The value is used to control the passenger compartment temperature and as the input signal to the central electronic module (CEM).

Outside temperature

Measurement range: -10 - 80°C

The climate control module (CCM) obtains the value via the control area network (CAN) from the passenger door module (PDM) (left-hand drive) or the driver door module (DDM) (right-hand drive).

The value is used to control the passenger compartment temperature.

Guide current for the blower fan motor power unit, value

Measurement range: 0-10 mA

The climate control module (CCM) calculates the value based on the signal from the control knob for the blower fan. With electronic climate control, the value is also affected by automatic climate control (AUTO position).

The value is used to control the power supply from the power unit to the blower fan motor.

Lower switch approval, status

The status displays whether the identity of a certain switch is permissible or missing compared with the permitted switch identities in the Car Configuration File.

Ok = Switch permitted

Faulty = Switch not permitted

Lower switch, status

Displays the status of a certain switch.

Off = Active signal

On = Signal not active

Lower switch identity, status

The status displays the function of a certain switch. The functions are as follows

Fold down head restraints

Folding power door mirrors

Private locking (boot lid)

STC

DSTC

Auxiliary lamps

Deadlock (temporary disengagement of the movement and tilt sensors in the alarm)

Reverse warning

Bi-fuel

Child-proof lock

Rear A/C

Temperature damper motor, left position, value

Measurement range: 0 - 100%

The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Temperature damper motor, right position, value

Measurement range: 0 - 100%

The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Recirculation damper motor position, value

Measurement range: 0 - 100%

The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Floor/ventilation damper motor position, value (Electronic climate control)

Measurement range: 0 - 100%

The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Defroster damper motor position, value (Electronic climate control)

Measurement range: 0 - 100%

The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Air distribution damper motor position, value (Manual climate control/standard)

Measurement range: 0 - 100%

The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Air distribution selector, defroster position, status (Manual climate control/standard)

The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.

Off = Inactive

On = Active

Air distribution selector, ventilation position, status (Manual climate control/standard)

The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.

Off = Inactive

On = Active

Air distribution selector, floor position, status (Manual climate control/standard)

The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.

Off = Inactive

On = Active

Air distribution selector, floor/defroster position, status (Manual climate control/standard)

The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.

Off = Inactive

On = Active

Temperature damper motor, left activation, value

Measurement range: 0 - U bat

The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Temperature damper motor, right activation, value

Measurement range: 0 - U bat

The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Recirculation damper motor activation, value

Measurement range: 0 - U bat

The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Floor/ventilation damper motor activation, value (Electronic climate control)

Measurement range: 0 - U bat

The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Defroster damper motor activation, value (Electronic climate control)

Measurement range: 0 - U bat

The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Air distribution damper motor activation, value (Manual climate control/standard)

Measurement range: 0 - U bat

The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Air quality sensor, value (Electronic climate control)

Measurement range 0-100%

The climate control unit calculates the air quality using the signal from the air quality sensor. The value is used to control the position of the recirculation motor.

The status displays whether the identity of a certain switch is permissible or missing compared with the permitted switch identities in the Car Configuration File.

Ok = Switch permitted.

Faulty = Switch not permitted.

Lower switch identity

The status displays the function of a certain switch. The functions are as follows

Adjustable head restraint

Retracting door mirrors

Private locking (trunk lid)

STC

DSTC

BLIS

Auxiliary lamps

Reduced alarm (temporary disengagement of the movement and tilt sensors in the alarm)

Back-up warning

Bi-fuel

Child-proof lock

Rear A/C

Four-C

Blind spot detection

Not defined

Lower switch LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for lower switches should be lit or not.

Lit = the LED must be lit.

Not lit = the LED must not be lit.

Lower switch

The parameter indicates whether the climate control module (CCM) recognizes whether the button for each switch is pressed in or not.

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

Status, seat heater right front

The parameter indicates the status of the right-hand front seat heating module (SHM).

The following statuses are available

OK, heating off -- Seat heating module (SHM) functioning, heating off.

OK, heating on -- Seat heating module (SHM) functioning, heating on.

Incorrect status 1 -- Incorrect heater pad, heating off.

Incorrect status 2 -- Faulty temperature sensor, heating off.

Incorrect status 3 -- Seat heating module (SHM) overheated, heating off.

Incorrect status 4 -- Communication problems, heating off.

Incorrect status 5 -- Other fault, heating off.

Incorrect status 6 -- Internal fault, heating off.

Status, seat heater left front

The parameter indicates the status of the left front seat heating module (SHM).

The following statuses are available

OK, heating off -- Seat heating module (SHM) functioning, heating off.

OK, heating on -- Seat heating module (SHM) functioning, heating on.

Incorrect status 1 -- Incorrect heater pad, heating off.

Incorrect status 2 -- Faulty temperature sensor, heating off.

Incorrect status 3 -- Seat heating module (SHM) overheated, heating off.

Incorrect status 4 -- Communication problems, heating off.

Incorrect status 5 -- Other fault, heating off.

Incorrect status 6 -- Internal fault, heating off.

Button heated rear windshield/door mirrors

The parameter indicates whether the climate control module (CCM) recognizes whether the button for the heated rear windshield/door mirrors is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

Max defroster button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for max defroster is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

Air distribution defroster button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for air distribution defroster is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

Air distribution ventilation button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for air distribution ventilation is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

Air distribution floor button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for air distribution floor is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

A/C button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for air conditioning (A/C) is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

Seat heater left front button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for the left front seat heater is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

Seat heater right front button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for the right front seat heater is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

AUTO button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for AUTO mode is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

Recirculation button

The parameter indicates whether the climate control module (CCM) recognizes whether the button for recirculation is pressed in or not.

The button is on the keypad for the climate control module (CCM).

Not pressed = the button is not pressed in.

Pressed = the button is pressed in.

AQS LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for the air quality sensor (AQS) should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Recirculation LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for recirculation should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

AUTO LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for AUTO should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Heated rear windshield LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for the heated rear windshield/door mirrors should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Max defroster LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for maximum defrosting should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Defroster LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for air distribution defroster should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Ventilation LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for air distribution ventilation should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Floor LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for floor air distribution should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

A/C ON LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for A/C ON should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

A/C OFF LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for A/C OFF should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Left seat heater low LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for left seat heater low should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Left seat heater high LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for left seat heater high should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Right seat heater low LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for right seat heater low should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Right seat heater high LED

The parameter indicates whether the climate control module (CCM) recognizes whether the LED for right seat heater high should be lit or not.

The LED is on the keypad for the climate control module (CCM).

Not lit = the LED must not be lit.

Lit = the LED must be lit.

Blower fan control, red LED

The parameter indicates whether the climate control module (CCM) recognizes whether the red LED for the blower fan control should be lit or not.

Lit = the LED must be lit.

Not lit = the LED must not be lit.

Blower fan control, green LED

The parameter indicates whether the climate control module (CCM) recognizes whether the green LEDs for the blower fan control should be lit or not.

Not lit = the LED must not be lit.

1 lit = 1 LED must be lit.

2 lit = 2 LEDs must be lit.

3 lit = 3 LEDs must be lit.

4 lit = 4 LEDs must be lit.

5 lit = 5 LEDs must be lit.

6 lit = 6 LEDs must be lit.

7 lit = 7 LEDs must be lit.

AQS signal (only ECC)

The parameter displays the signal from the air quality sensor (AQS). The climate control module (CCM) uses the signal to regulate the damper motor module (DMM) recirculation.

Off = no increase or reduction in pollutant level.

Level 1 = slow increase in pollutant level.

Level 2 = medium increase in pollutant level.

Level 3 = rapid increase in pollutant level.

Evaporator temperature

The value indicates the temperature from the evaporator temperature sensor. The value is used by the climate control module (CCM) to regulate activation of the air conditioning (A/C) compressor.

Measurement range -100°C-100°C.

With the ignition off and a cold engine, the value must correspond with the ambient temperature.

When the engine is running and the A/C is activated, the climate control module (CCM) will regulate the compressor as follows

  1. Compressor on at 10°C.
  2. Compressor off at 6°C.

Passenger compartment temperature sensor (only ECC)

The parameter indicates the value from the passenger compartment temperature sensor. The climate control module (CCM) uses the signal to regulate the climate in the passenger compartment in the AUTO position.

Measurement range -40-90°C.

The value must correspond to the ambient temperature.

Desired position, damper motor, defroster

The value indicates how much the damper for the defroster should be open to correspond to the desired climate control. The climate control module (CCM) transmits the value to the damper motor module (DMM) defroster via the LIN bus.

Measurement range 0-100%.

100% is full capacity.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, defroster

The value indicates how much the damper for the defroster is open. The climate control module (CCM) receives the value from the damper motor module (DMM) for the defroster via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Desired position, damper motor, recirculation

The value indicates how much the damper for recirculation should be open to correspond to the desired climate control. The climate control module (CCM) transmits the value to the damper motor module (DMM) recirculation via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, recirculation

The value indicates how much the damper for recirculation is open. The climate control module (CCM) receives the value from the damper motor module (DMM) recirculation via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Desired position, damper motor, temperature left

The value indicates how much the damper for temperature left should be open to correspond to the desired climate control. The climate control module (CCM) transmits the value to the damper motor module (DMM) temperature left via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, temperature left

The value indicates how much the damper for temperature left is open. The climate control module (CCM) receives the value from the damper motor module (DMM) temperature left via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Desired position, damper motor, temperature right

The value indicates how much the damper for temperature right should be open to correspond to the desired climate control. The climate control module (CCM) transmits the value to the damper motor module (DMM) for temperature right via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, temperature right

The value indicates how much the damper for temperature right is open. The climate control module (CCM) receives the value from the damper motor module (DMM) for temperature right via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Desired position, damper motor, air distribution

The value indicates how much the damper for air distribution should be open to correspond to the desired climate control. The climate control module (CCM) transmits the value to the damper motor module (DMM) air distribution via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, air distribution

The value indicates how much the damper for air distribution is open. The climate control module (CCM) receives the value from the damper motor module (DMM) air distribution via the LIN bus.

Measurement range 0-100%.

0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Requested blower fan speed

The value indicates how much the blower fan must blow to correspond to the desired climate control. The climate control module (CCM) controls the blower fan speed by transmitting a signal to the central electronic module (CEM).

Measurement range 0-100%.

0% corresponds to the blower fan switched off, 100% corresponds to maximum blower fan speed.

Power supply

The value indicates the power supply to the climate control module (CCM).

Measurement range 0-50 V.

Normal value approximately 12 V (battery voltage).

Contents

Select type of description.

  1. See «Description of frozen values»(ref-461767-S16795008262012040200000)
  2. See «Status identifier, description»(ref-440272-S15039250262011121400000)
  3. See «Counters, description»(ref-440272-S37949496482011121400000)