Installation

To install, reverse removal procedure. Install drive belt. See BELT TENSION under ADJUSTMENTS. Tighten generator bolts to specification. See TORQUE SPECIFICATIONS .

Removal - V8

  1. Remove V-bank cover.
  2. Remove engine under cover sub-assembly No. 1.
  3. Disconnect battery cables.
  4. Remove serpentine drive belt.
  5. Remove battery.
  6. Disconnect generator wire harness connector. Remove nut and wire from "B" terminal on back of generator.
  7. Remove 2 mounting bolts and wire harness clamp bracket from generator.
  8. Remove 2 bolts and generator.

To install, reverse removal procedure. Tighten generator bolts to specification. See TORQUE SPECIFICATIONS .