SERVICE DATA [07/2013 - 12/2013]

Starter assemblyStandard currentBelow 90 A at 11.5 V
Starter armature assemblyStandard runoutFor Manual Transmission0.05 mm (0.002 in.)
For Automatic Transmission0.02 mm (0.0008 in.)
Maximum runoutFor Manual Transmission0.10 mm (0.004 in.)
For Automatic Transmission0.05 mm (0.002 in.)
Standard depth Segment - MoldFor Manual Transmission0.50 mm (0.020 in.)
For Automatic Transmission0.7 mm (0.0276 in.)
Minimum depth Segment - MoldFor Automatic Transmission0.20 mm (0.0079 in.)
Standard resistanceSegment - Segment for Automatic TransmissionBelow 1 ohms
Commutator - Armature coil core for Automatic Transmission10 kohms or higher
Standard diameterFor Automatic Transmission29 mm (1.1417 in.)
Minimum diameterFor Automatic Transmission28 mm (1.1024 in.)
Brush lengthStandard lengthFor Manual Transmission12.3 mm (0.484 in.)
For Automatic Transmission14.4 mm (0.5669 in.)
Minimum lengthFor Manual Transmission7.0 mm (0.276 in.)
For Automatic Transmission9.0 mm (0.3543 in.)
Standard brush spring forceFor Manual Transmission15.9 to 19.5 N (1.6 to 2.0 kgf, 3.6 to 4.4 lbf)
Minimum brush spring forceFor Manual Transmission2.5 N (0.3 kgf, 0.6 lbf)
Standard resistance for Automatic TransmissionA - B A - C B - D C - D10 kohms or higher
A - D B - CBelow 1 ohms
Starter magnetic switch assemblyStandard resistance Terminal 50 - Terminal CFor Manual TransmissionBelow 1 ohms
For Automatic TransmissionBelow 1 ohms
Standard resistance Terminal 50 - Switch bodyFor Manual TransmissionBelow 1 ohms
For Automatic TransmissionBelow 2 ohms
Standard resistance Terminal 30 - Terminal CFor Manual Transmission1 Mohms or higher
Ignition switch assemblyStandard resistance All combinations of all terminalsLOCK10 kohms or higher
Standard resistance 2 (AM1) - 3 (ACC)ACCBelow 1 ohms
Standard resistance 2 (AM1) - 3 (ACC) - 4 (IG1) 6 (IG2) - 7 (AM2)ONBelow 1 ohms
Standard resistance 1 (ST1) - 2 (AM1) - 4 (IG1) 6 (IG2) - 7 (AM2) - 8 (ST2)STARTBelow 1 ohms
Starter relaySpecified condition1 - 2 (Battery voltage not applied to terminals 1 and 2) (Measured temperature : 20 °C (68 °F))93.8 to 136.4 kohms
3 - 5 (Battery voltage is applied between terminals 1 and 2)Below 1 ohms
3 - 5 (Battery voltage is not applied between terminals 1 and 2)10 kohms or higher
Inhibitor relaySpecified condition1 - 2 (Battery voltage not applied to terminals 1 and 2) (Measured temperature : 20 °C (68 °F))93.8 to 136.4 kohms
3 - 5 (Battery voltage is applied between terminals 1 and 2)Below 1 ohms
3 - 5 (Battery voltage is not applied between terminals 1 and 2)10 kohms or higher

SERVICE DATA [12/2013 - ]

Starter assemblyStandard currentBelow 90 A at 11.5 V
Starter armature assemblyStandard runoutFor Manual Transmission0.05 mm (0.002 in.)
For Automatic Transmission0.02 mm (0.0008 in.)
Maximum runoutFor Manual Transmission0.10 mm (0.004 in.)
For Automatic Transmission0.05 mm (0.002 in.)
Standard depth Segment - MoldFor Manual Transmission0.50 mm (0.020 in.)
For Automatic Transmission0.7 mm (0.0276 in.)
Minimum depth Segment - MoldFor Automatic Transmission0.20 mm (0.0079 in.)
Standard resistanceSegment - Segment for Automatic TransmissionBelow 1 ohms
Commutator - Armature coil core for Automatic Transmission10 kohms or higher
Standard diameterFor Automatic Transmission29 mm (1.1417 in.)
Minimum diameterFor Automatic Transmission28 mm (1.1024 in.)
Brush lengthStandard lengthFor Manual Transmission12.3 mm (0.484 in.)
For Automatic Transmission14.4 mm (0.5669 in.)
Minimum lengthFor Manual Transmission7.0 mm (0.276 in.)
For Automatic Transmission9.0 mm (0.3543 in.)
Standard brush spring forceFor Manual Transmission15.9 to 19.5 N (1.6 to 2.0 kgf, 3.6 to 4.4 lbf)
Minimum brush spring forceFor Manual Transmission2.5 N (0.3 kgf, 0.6 lbf)
Standard resistance for Automatic TransmissionA - B A - C B - D C - D10 kohms or higher
A - D B - CBelow 1 ohms
Starter magnetic switch assemblyStandard resistance Terminal 50 - Terminal CFor Manual TransmissionBelow 1 ohms
For Automatic TransmissionBelow 1 ohms
Standard resistance Terminal 50 - Switch bodyFor Manual TransmissionBelow 1 ohms
For Automatic TransmissionBelow 2 ohms
Standard resistance Terminal 30 - Terminal CFor Manual Transmission1 Mohms or higher
Ignition switch assemblyStandard resistance All combinations of all terminalsLOCK10 kohms or higher
Standard resistance 2 (AM1) - 3 (ACC)ACCBelow 1 ohms
Standard resistance 2 (AM1) - 3 (ACC) - 4 (IG1) 6 (IG2) - 7 (AM2)ONBelow 1 ohms
Standard resistance 1 (ST1) - 2 (AM1) - 4 (IG1) 6 (IG2) - 7 (AM2) - 8 (ST2)STARTBelow 1 ohms
Engine switchStandard resistance 5 (SSW1) - 6 (AGND) 1 (SSW2) - 6 (AGND)PushedBelow 1 ohms
Standard resistance 5 (SSW1) - 6 (AGND) 1 (SSW2) - 6 (AGND)Not pushed10 kohms or higher
Starter relaySpecified condition1 - 2 (Battery voltage not applied to terminals 1 and 2) (Measured temperature : 20 °C (68 °F))93.8 to 136.4 kohms
3 - 5 (Battery voltage is applied between terminals 1 and 2)Below 1 ohms
3 - 5 (Battery voltage is not applied between terminals 1 and 2)10 kohms or higher
Inhibitor relaySpecified condition1 - 2 (Battery voltage not applied to terminals 1 and 2) (Measured temperature : 20 °C (68 °F))93.8 to 136.4 kohms
3 - 5 (Battery voltage is applied between terminals 1 and 2)Below 1 ohms
3 - 5 (Battery voltage is not applied between terminals 1 and 2)10 kohms or higher
ST cut relaySpecified condition1 - 2 (Battery voltage not applied to terminals 1 and 2) (Measured temperature : 20 °C (68 °F))93.8 to 136.4 kohms
3 - 4 (Battery voltage not applied to terminals 1 and 2)Below 1 ohms
3 - 4 (Battery voltage applied to terminals 1 and 2)10 kohms or higher
3 - 5 (Battery voltage not applied to terminals 1 and 2)10 kohms or higher
3 - 5 (Battery voltage applied to terminals 1 and 2)Below 1 ohms
IGS cut relaySpecified condition1 - 2 (Battery voltage not applied to terminals 1 and 2) (Measured temperature : 20 °C (68 °F))93.8 to 136.4 kohms
3 - 5 (Battery voltage not applied to terminals 1 and 2)10 kohms or higher
3 - 5 (Battery voltage applied to terminals 1 and 2)Below 1 ohms