Home/Pontiac/G6/Pontiac G6 I (2004-2009)/Repair manual/Communication Devices/Computer/integrating Systems: Adjustments
Contents Wiring diagrams Section: Communication Devices All sections

Computer/integrating Systems: Adjustments Pontiac G6 I

Remote Start calibration

In order to setup the remote start feature a Techline Terminal using the Pass-Thru routine must be used. With the scan tool powered down, attach it to the vehicle then connect the Techline Terminal's RS-232 cable to the scan tool. Select Service Programming System from the Techline Terminal main screen. Select the Pass-Thru procedure from the Techline Terminal's menu selections and follow all on-screen directions. Ensure the correct programming procedure is selected based on the component being replaced or programmed. Configure the remote start feature to match the original RPO content on the vehicle. Refer to Service Programming System (SPS) in Programming and Setup for information on SPS.

BPP Sensor Calibration

IMPORTANTIf the BCM or the brake apply sensing system (BAS) sensor is replaced, a brake pedal position (BPP) sensor calibration must be performed.

Perform the BPP Sensor Calibration using a scan tool. Refer to Brake Pedal Position Sensor Calibration in Lighting Systems, for the BPP calibration procedure.