Technical Data
Cooling
| Engine | 15 D/X 15 DT (4EC1) | 15 DT (4EC1) | 17 D (4EE1) | X 17 D (4EE1) | |
|---|---|---|---|---|---|
| Radiator | |||||
| Type | Cross-flow | Cross-flow | Cross-flow | Cross-flow | |
| Radiator core surface | cm 2 | 1850 | 1850 | 1850 | 1850 |
| Coolant Filling Quantities | |||||
| Cooling system capacity | in ltr. | 6.0 | 6.3 | 6.0 | 6.0 |
Cooling
| Engine | All | |||||||
|---|---|---|---|---|---|---|---|---|
| Anti-freeze Mixture | ||||||||
| When correcting, use Opel radiator anti-freeze 90 297 545 (19 40 656). A concentration that is too low puts the anti-freeze and corrosion protection at risk. The anti-freeze protection should go down to -30 �C. | ||||||||
| down to -10 �C | down to -20 �C | down to -30 �C | down to -40 �C | |||||
| Required | Quantity in litres | Quantity in litres | Quantity in litres | Quantity in litres | ||||
| Capacity | Water | Anti-freeze | Water | Anti-freeze | Water | Anti-freeze | Water | Anti-freeze |
| (in litres) | (80 %) | (20 %) | (66 %) | (34 %) | (56 %) | (44 %) | (48 %) | (52 %) |
| 6.0 | 4.8 | 1.2 | 4.0 | 2.0 | 3.4 | 2.6 | 2.9 | 3.1 |
| 6.3 | 5.0 | 1.3 | 4.2 | 2.1 | 3.5 | 2.8 | 3.0 | 3.3 |
Cooling
| Engine | 15 D (4EC1), 15 DT, X 15 DT (T4EC1), 17 D, X 17 D (4EE1) | |
|---|---|---|
| Fan | ||
| Number of blades | 5 | |
| Blade pattern | asymmetric | |
| Diameter | mm | 305 |
| Type | Electro-fan (2-speed). 1st speed - 120 W | |
| 2nd speed - 220 W | ||
| Thermoswitch | ||
| Switch on | �C | 100 |
| Switch off | �C | 95 |
| Thermostat | ||
| Start of opening | �C | 88 |
| Fully open | �C | 106 |
| Identification | 88 | |
| Type | Bypass/twin valve | |
| Closure Cap | ||
| Identification | kPa (bar) | 120 to 135 (1.20 to 1.35) |
| Opening pressure | 120 |