Power Module Replace
Remove
- Disconnect the negative battery cable.
- Remove the glove box lower panel cover. Refer to Instrument Compartment Replace .
- Disconnect the electrical connector at the resistor.
- Remove the screws from the resistor.
- Remove the resistor from the A/C module by gently pulling the resistor downward.
Install
- Install the new resistor into the heater/air distributor case assembly with the screws.
Tighten
Tighten the blower motor resistor screws to 6 N•m (53 lb-in).
- Connect the electrical connector at the resistor.
- Connect the negative battery cable.
- Confirm the proper performance of the blower.
- Install the glove box lower panel cover. Refer to Instrument Compartment Replace .