GENERAL SPECIFICATIONS
| Item | Specification |
|---|---|
| Type | Positive battery positive voltage sensing |
| Identification number | A3TL0081 |
| Part No. | 1800A155 |
| Rated output V/A | 12/120 |
| Voltage regulator | Electronic built-in type |
GENERAL SPECIFICATIONS
SERVICE SPECIFICATIONS
| Item | Standard value | Limit | |
|---|---|---|---|
| Regulated voltage (Ambient temperature at voltage regulator) | 20°C (--4°F) | 14.2 - 15.4 | |
| 20°C (68°F) | 13.9 - 14.9 | ||
| 60°C (140°F) | 13.4 - 14.6 | ||
| 80°C (176°F) | 13.1 - 14.5 | ||
| Generator output line voltage drop (at 30 A) V | Maximum 0.3 | ||
| Output current | 70 % of normal output current | ||
| Field coil resistance ohms | Approximately 2 - 5 | ||
| Brush protrusion length mm (in) | Minimum 2 (0.08) | ||
SERVICE SPECIFICATIONS
See also:
• BATTERY TEST