- Drain the engine cooling system.
- Remove the degas bottle.
- Loosen pulley bolts. (Scheme 21)
- Remove the drive belt.
- Remove the water pump pulley.
- Remove the generator.
- Remove water pump bolts. (Scheme 22)and (Scheme 23).
- Remove the water pump.
Installation
Note. The sealing surfaces must be clean and dry prior to installation of the water pump.
- Clean the sealing surfaces, install a new O-ring seal and lubricate with a non-petroleum based lubricant. (Scheme 24)
- Position the water pump. Install the bolts. Tighten to specification. See «TORQUE SPECIFICATIONS»(ref-1338-S15062982612000031300000).
- Install the generator.
- Position the water pump pulley. Install the bolts. Tighten to specification. See «TORQUE SPECIFICATIONS»(ref-1338-S15062982612000031300000).
- Install the drive belt.
- Install the degas bottle.
- Fill and bleed the cooling system.