INSPECTION
- Adjusting method for T/M control cable
Scheme 61
- Set room side lever and T/M side lever to "N" position.
- Connect room side lever and shift cable.
- Connect T/M side lever to cable in a following orders. Push cable lightly in direction of arrow shown to eliminate FREE PLAY of cable. Tighten adjusting nut(C).
- After adjusting according to (2)-(4), verify that A/T shift lever can be properly moved to each gear position.