GENERATOR SPECIFICATIONS
| Application | Specification | |
|---|---|---|
| Generator Amperage Rating | ||
| 2.0L | 110 Amps | |
| 2.3L | 124 Amps | |
| Load Test (1) | ||
| With Tester Load (2) | (3) | |
| Without Tester Load (4) | (5) | |
| No-Load Test (1) (2) | 13-15 Volts | |
| (1) All load tests are performed with engine running at 2000 RPM. (2) All accessories off. (3) Adjust tester load bank to determine generator output. (4) Perform this test with engine at 1500 RPM. (5) The voltage should be in the range of 14.1 to 15.1 volts. If the voltage increase is less than 2.5 volts over the base voltage, perform the Load Test. | ||
| (1) | All load tests are performed with engine running at 2000 RPM. |
| (2) | All accessories off. |
| (3) | Adjust tester load bank to determine generator output. |
| (4) | Perform this test with engine at 1500 RPM. |
| (5) | The voltage should be in the range of 14.1 to 15.1 volts. If the voltage increase is less than 2.5 volts over the base voltage, perform the Load Test. |
GENERATOR SPECIFICATIONS
TORQUE SPECIFICATIONS
| Application | Ft. Lbs. (N.m) | |
|---|---|---|
| Generator Mounting Bolts | ||
| 2.0L SPI | 35 (48) | |
| 2.0L Zetec-E | 18 (25) | |
| INCH Lbs. (N.m) | ||
| Generator B+ Terminal Nut | 71 (8) | |
TORQUE SPECIFICATIONS