Cooling system
Engine compartment
"a" bleed screw(s) (main circuit)
(1) expansion chamber
(2) coolant pump
(3) coolant outlet housing
(4) cooling radiator
(5) fan
(6) engine oil cooler
Passenger compartment
(b) bleeding the secondary system (*)
(7) main heater matrix
(8) secondary heater matrix (*)
(9) secondary heater matrix electrovalve (*)
(10) secondary heater matrix pump (*)
(11) coolant outlet housing
(*) version with additional heating
Data
| capacity of the cooling system with heater and secondary heater matrix | 8,50 litres |
|---|---|
| opening of thermostatic regulator | 83 °C |
| triggering threshold of the fan | 96 °C |
| number X fan speed | 2 x 300 Watts |
| air conditioning cut-off threshold | 115 °C |
| warning threshold | 118 °C |
| post-cooling threshold | 105 °C (for a maximum of 6 minutes) |
| surface area of the cooling radiator | 21 dm2 |
| pressurisation | cap with 1,4 bar rating |
| coolant temperature sensor located on the coolant outlet housing | green connector |
| engine coolant level sensor | located on the header tank |