Shift Solenoid Valve State and Gear Ratio
| Gear | Shift SOL 1 | Shift SOL 2 | Aux Line BOOST Valve PC SOL 5 N.L. | 1-3 CL PC SOL 4 N.L. | Hybrid Low, 1-2 CL PC SOL 3 N.H. | Hybrid Direct, 2-3-4 CL PC SOL 2 N.H. | Isolator Valve PC SOL 1 N.H. | Gear Ratio |
| Park (Engine Running) | OFF | OFF | OFF | OFF | OFF | OFF | ON | |
| Reverse (EVT Engine Running) | OFF | OFF | OFF | OFF | ON | OFF | ON | 3.692 |
| Neutral (Engine Running | OFF | OFF | OFF | OFF | OFF | OFF | ON | |
| EVT Mode 1 (Engine Running) | OFF | OFF | OFF | OFF | ON | OFF | ON | Infinity to 1.70 |
| EVT Mode 1 (Engine Off) | OFF | OFF | ON | OFF | ON | OFF | OFF | Infinity to 1.70 |
| Drive 1st | ON | OFF | OFF | ON | ON | OFF | ON | 3.692 |
| Drive 2nd | ON | OFF | OFF | OFF | ON | ON | ON | 1.705 |
| Drive 3rd | ON | ON | OFF | ON | OFF | ON | ON | 1.000 |
| Drive 4th | ON | ON | OFF | OFF | ON | ON | ON | 0.738 |
| EVT Mode 2 (From 4th) | OFF | ON | OFF | OFF | OFF | ON | ON | |
| Power Off Low Default | OFF | OFF | OFF | OFF | ON | ON | ON | |
| Power Off High Default | OFF | OFF | OFF | OFF | ON | ON | ON | |
| For shift solenoids 1 and 2, "ON" = Solenoid Energized (Pressurized) "OFF" = Solenoid De-energized (No Pressure). For pressure control solenoids, "ON" = Pressurized, "OFF" = No Pressure |
Transmission Internal Mode Switch Logic
| IMS Circuits/Parameter | Selector Position |
| Park | Reverse | Neutral | Drive | Manual |
| Direction Switch Operating Conditions: Ignition ON, range selector in appropriate gear |
| Direction IMS D1 | HIGH | HIGH | LOW | LOW | LOW |
| Direction IMS D2 | LOW | LOW | HIGH | HIGH | HIGH |
| Direction IMS R1 | HIGH | LOW | LOW | HIGH | HIGH |
| Direction IMS R2 | LOW | HIGH | HIGH | LOW | LOW |
| Direction IMS Start | LOW | HIGH | LOW | HIGH | HIGH |
| Range Switch Operating Conditions: Ignition ON, range selector in appropriate gear |
| IMS A | LOW | LOW | HI | HI | HI |
| IMS B | HI | LOW | LOW | LOW | HI |
| IMS C | HI | HI | HI | LOW | LOW |
| IMS P | LOW | HI | LOW | HI | LOW |
| Always HIGH status: Open/short to voltage condition Always LOW status: Short to ground condition Every status HIGH for either switch indicates an open ground circuit or connector for that portion of the IMS. |
Internal Mode Switch (IMS)