A short to ground is detected on the mirror heating element supply voltage circuit while the heated mirrors.
Action Taken When the DTC Sets
The affected heated mirror will not be activated.
Conditions for Clearing the DTC
- A current DTC will clear when the fault is no longer present.
- A history DTC will clear after 40 malfunction-free ignition cycles.
Reference Information
Schematic Reference
Outside Rearview Mirror Schematics
Connector End View Reference
Mirror Connector End Views
Description and Operation
Outside Mirror Description and Operation (with RPO DL3) or Outside Mirror Description and Operation (without RPO DL3)
Electrical Information Reference
- «Circuit Testing»(ref-278019-S01379251932008012100000)
- «Connector Repairs»(ref-278019-S06982211772008012100000)
- «Testing for Intermittent Conditions and Poor Connections»(ref-278019-S21810776732008012100000)
- «Wiring Repairs»(ref-278019-S25320832652008012100000)