FASTENER TIGHTENING SPECIFICATIONS
| Component | Fastener Size | Nm |
|---|---|---|
| Wiper Arm to Wiper Motor Nut | 17 |
WIPER MOTOR BOLT TIGHTENING SEQUENCE AND SPECIFICATION
Tighten the bolts -1, 2 and 3- in sequence in 2 stages as follows
1. Install by hand until snug.
2. Tighten to 8 Nm.
WASHER FLUID RESERVOIR BOLT TIGHTENING SEQUENCE AND SPECIFICATION
Tighten the washer fluid bolts -3 and 4- in the sequence specified
1. Tighten the bolt -3- to 7 Nm.
2. Tighten the bolt -4- to 7 Nm.
See also:
• Wiper/Washer Systems