Contents Section: On Board Diagnostic (OBD) - Suspension & Tire Pressure Monitoring All sections

Basic setting (function 04) Audi A6 C5 рестайлинг

Basic setting (function 04)

If the control module, the vehicle level sensor or the entire unit is replaced, the basic setting procedure (Adaptation) must be performed. The tolerance for the setpoint specification ( normal level 402 mm) is specified at +/- 5 mm on the axle side.

If the new control system does not stabilize, the engine must be started (it is possible that the pressure in the pressure accumulator is no longer sufficient) and all doors must be closed.

The following values are then learned

  1. Measured height distance at front left (Channel 01)
  2. Measured height distance at front right (Channel 02)
  3. Measured height distance at rear left (Channel 03)
  4. Measured height distance at rear right (Channel 04)