Test equipment display during load test
| Display on battery tester | Delivery Service | Inspection Service Long Life Service |
|---|---|---|
| Battery very good | Battery OK | Battery OK |
| Battery good | Recharge battery (1) | Battery OK |
| Battery bad | Recharge battery (1) | Recharge battery (1) |
| Battery faulty | Replace battery | Replace battery (2) |
| (1) Perform battery load testing again after recharging the battery. If "battery good" "Battery bad" is displayed again after recharging the battery replace the battery. (2) Replace battery after discussion with customer. | ||
| (1) | Perform battery load testing again after recharging the battery. If "battery good" "Battery bad" is displayed again after recharging the battery replace the battery. |
| (2) | Replace battery after discussion with customer. |
TEST EQUIPMENT DISPLAY DURING LOAD TEST
Note. Please note before disconnecting the battery, see INSTALLING .
Explanations for battery load test
The battery voltage lowers (high current flow) caused by high load during this test.
If a battery is in working order battery voltage will only drop to lowest voltage.
If the battery is faulty or charged insufficiently the battery voltage drops quickly below the given minimum voltage.
After completing test these low voltage values remain over an extremely long period, voltage increases very slowly again.