FRONT CONDENSATION WATER DRAIN HOSE WITH VALVE, CHECKING
Remove footwell trim on front passenger side. Refer to Removal and Installation
Scheme 33
- The condensation water drain hose -1- must be able to be connected to connection of heating and A/C unit -2- without pre-tension.
- The condensation water drain hose must not be constricted in its cross section through the insulation mat.
Rework insulation mat if necessary.
- Condensation water drain hose must sit securely on connection for condensation water hose on heating and A/C unit.
The valve is located in lower right of engine compartment below the plenum chamber bulkhead.
Note. For the purpose of a better illustration, the valve -1- is shown with subframe removed. The condensation drainage valve may not be bonded by wax or underbody protection, it must close correctly.
Check valve -1- from below when vehicle is raised.
Scheme 34
- Condensation water drain hose must fit securely on connection of heating and A/C unit.
- Valve may not be bonded by wax or underbody protection, it must close correctly.
- Condensation water drain hose to valve must not be kinked or pinched.
Check valve from below when vehicle is raised.