PROCEDURE
- INITIALIZE POWER WINDOW CONTROL SYSTEM Initialize the power window regulator motor assembly (on the driver side), refer to «INITIALIZATION»(ref-422307-S33663556452011092600000) . Check that the power window operates normally by opening and closing the window. OK Driver side power window operates normally. NG --> See step 4 OK: Go to next step
- CHECK WHETHER PARTS HAVE BEEN INSTALLED CORRECTLY Check that the power window components (on the driver side) are installed correctly. OK Power window components (on driver side) are installed correctly. HINT: When the power window components are installed correctly, the problem has been caused by battery disconnection while the ignition switch is on (IG), improper installation of the power window components or the motor being overheated. NG --> INSTALL PARTS CORRECTLY OK: Go to next step
- CHECK DTC OUTPUT Turn the ignition switch off. Wait for at least 10 seconds, and then turn the ignition switch on (IG). Check whether the DTC output recurs. Result Display (DTC Output) Proceed to B2311 A No output B A --> See step 4 B --> END
- REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side). Refer to «REMOVAL»(ref-422557-S31617504892011092600000)
- CHECK DTC OUTPUT Turn the ignition switch off. Wait for at least 10 seconds, and then turn the ignition switch on (IG). Check whether the DTC output recurs. Result Result Proceed to B213 is not output A B2313 is output B A --> See step 4 B: Go to next step
- INITIALIZE SYSTEM (POWER WINDOW CONTROL SYSTEM) Turn the ignition switch on (IG) and initialize the power window regulator motor (on the driver side), refer to «INITIALIZATION»(ref-422307-S33663556452011092600000) . Turn the ignition switch off. Wait for at least 10 seconds, and then turn the ignition switch on (IG). Check whether the DTC output recurs. Result Result Proceed to B2313 is output A B213 is not output B B --> END A --> See step 3
- REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side). Refer to «REMOVAL»(ref-422557-S31617504892011092600000)
- USE SIMULATION METHOD TO CHECK. Refer to «HOW TO PROCEED WITH TROUBLESHOOTING»(ref-422289-S34804177702011092600000)
- INITIALIZE POWER WINDOW CONTROL SYSTEM Initialize the power window regulator motor assembly (on the driver side), refer to «INITIALIZATION»(ref-422307-S33663556452011092600000) . Check that the power window operates normally by opening and closing the window. OK AUTO UP / DOWN function operates normally. NG --> See step 2 OK --> END (PROBLEM DUE TO INITIALIZATION FAILURE)
- CHECK WINDOW GLASS SLIDING MOVEMENT (for Driver Side) Remove the window regulator. Install the window glass onto the door glass run. Check if the door window regulator operates smoothly. Check that the window glass slides smoothly when sliding it up by hand. OK Door window glass slides smoothly. HINT: Ensure the following: The window glass fits with the glass run without improper contact. Neither deformation nor foreign objects in the glass run. NOTE: Perform initialization again. NG --> FIT WINDOW GLASS CORRECTLY (REMOVE FOREIGN OBJECTS CAUSING IMPROPER FITTING OR REPLACE PARTS) OK --> See step 3
- REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side). Refer to «REMOVAL»(ref-422557-S31617504892011092600000)