SERVICE DATA
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 6.9 to 7.9 ohms |
CAMSHAFT OIL CONTROL VALVE
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (M-) - 2 (M+) | 20°C (68°F) | 0.3 to 100 ohms |
THROTTLE BODY
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (THA) - 2 (E2) | 20°C (-4°F) | 13.6 to 18.4 kohms |
| 20°C (68°F) | 2.21 to 2.69 kohms | |
| 60°C (140°F) | 0.49 to 0.67 kohms |
MASS AIR FLOW METER
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Cold | 1630 to 2740 ohms |
| Hot | 2065 to 3225 ohms |
CRANKSHAFT POSITION SENSOR
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 2.32 to 2.59 kohms |
| 80°C (176°F) | 0.310 to 0.326 kohms |
ENGINE COOLANT TEMPERATURE SENSOR
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 120 to 280 kohms |
KNOCK SENSOR
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| For Bank 1: 1 (HA1A) - 2 (+B) for Bank 2: 1 (HA2A) - 2 (+B) | 20°C (68°F) | 1.8 to 3.4 ohms |
| For Bank 1: 1 (HA1A) - 4 (A1A-) for Bank 2: 1 (HA2A) - 4 (A2A-) | Always | 10 kohms or higher |
AIR FUEL RATIO SENSOR
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| For Bank 1: 2 (HT1B) - 1 (+B) for Bank 2: 1 (HT2B) - 2 (+B) | 20°C (68°F) | 11 to 16 ohms |
| For Bank 1: 2 (HT1B) - 3 (E2) for Bank 2: 1 (HT2B) - 4 (E2) | Always | 10 kohms or higher |
HEATED OXYGEN SENSOR
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2A-2 - 2D-1 | When battery voltage is not applied between 2A- 7 and 2A-17 | 10 kohms or higher |
| When battery voltage is applied between 2A-7 and 2A-17 | Below 1 ohms |
A/F SENSOR HEATER RELAY