Contents Wiring diagrams Section: Automatic Trans All sections

B2705 05 Saturn Aura I

Automatic Trans ~147 words

This DTC sets if the automatic transmission shift lock control solenoid control circuit is open or shorted to voltage.

Action Taken When the DTC Sets

The BCM will not attempt to enable the voltage supply circuit of the automatic transmission shift lock control solenoid until the next key cycle.

Conditions for Clearing the DTC

  1. A current DTC will clear when the malfunction is no longer present and the ignition switch is cycled.
  2. All BCM history codes will clear after 100 ignition cycles with no current codes active during the 100 ignition cycles.

Reference Information

Schematic Reference

Shift Lock Control Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Automatic Transmission Shift Lock Control Description and Operation

Electrical Information Reference

  1. «Circuit Testing»(ref-301517-S12739748792008101700000)
  2. «Connector Repairs»(ref-301517-S02286547552008101700000)
  3. «Testing for Intermittent Conditions and Poor Connections»(ref-301517-S37460750252008101700000)
  4. «Wiring Repairs»(ref-301517-S19995224182008101700000)

Scan Tool Reference

Control Module References for scan tool information