Contents Wiring diagrams Section: Air Conditioning All sections

Technical Data Opel Vectra C

Switch pressures (Absolute pressures)ONOFF
Low pressurekPa>270<230
High pressurekPa<2400>3100
Fan
Pressure stage 1kPa>1300<1000
Pressure stage 2kPa>1800<1500
Pressure stage 3kPa>2200<1800
Pressure stage 4kPa>2500<2200
Switch temperaturesONOFF
Fan
Temperature stage 1°C>96<94
Temperature stage 2°C>99<97
Temperature stage 3°C>102<100
Temperature stage 4°C>105>103
Fan run-on°C>105after 3 min or <96 °C
Compressor°C<119>118
Compressor (at ambient temperature)°C0-3