C-15, Blower Controller Command Circuit Opel Vectra B

C-15, Blower Controller Command Circuit

C-15, Blower Controller Command Circuit
TestWork Order DescriptionNominal Value
T01Check: Short to Voltage/Ground/Interruption of Voltage Supply
Ignition OFF Disconnect wiring harness connector from: U28 Adjustment Unit ASM - Electronic Climate Control Measure voltage between the following terminals: U28 Adjustment Unit ASM - Electronic Climate Control Wiring Harness Connector (wiring harness side) Terminal 17 (26P) & Groundless than 0.1 V
Yes: T02No: E09
T02Check: Short to Voltage/Ground of Voltage Supply Circuit
Ignition ON Ignition key in ignition lock position II Measure voltage between the following terminals: U28 Adjustment Unit ASM - Electronic Climate Control Wiring Harness Connector (wiring harness side) Terminal 17 (26P) & Groundgreater than 11.5 V
Yes: T03No: T04
T03Check: Component
Ignition key in ignition lock position III Measure voltage between the following terminals: U28 Adjustment Unit ASM - Electronic Climate Control Wiring Harness Connector (wiring harness side) Terminal 17 (26P) & Groundless than 0.1 V
Yes: E01No: E02
T04Check: Short to Ground/Interruption of Voltage Supply Circuit
Disconnect wiring harness connector from: M10 Motor - Blower, Air Conditioning Measure voltage between the following terminals: M10 Motor - Blower, Air Conditioning Wiring Harness Connector (wiring harness side) Terminal A & Groundgreater than 11.5 V
Yes: T05No: E08
T05Check: Short to Voltage/Interruption of Voltage Supply Circuit
Measure voltage between the following terminals: M10 Motor - Blower, Air Conditioning Wiring Harness Connector (wiring harness side) Terminal A & M10 Motor - Blower, Air Conditioning Wiring Harness Connector (wiring harness side) Terminal Bgreater than 11.5 V
Yes: T06No: E07
T06Check: Short to Ground of Signal Circuit
Ignition OFF Disconnect wiring harness connector from: Blower control unit Measure resistance between the following terminals: U28 Adjustment Unit ASM - Electronic Climate Control Wiring Harness Connector (wiring harness side) Terminal 17 (26P) & Groundgreater than 100 kOhm
Yes: T07No: E06
T07Check: Interruption of Signal Circuit
Measure resistance between the following terminals: U28 Adjustment Unit ASM - Electronic Climate Control Wiring Harness Connector (wiring harness side) Terminal 17 (26P) & Blower control unit Wiring Harness Connector (wiring harness side) Terminal A1less than 2 Ohm
Yes: T08No: E05
T08Check: Component
Connect wiring harness connector to: M10 Motor - Blower, Air Conditioning Connect fused jumper wire to: Blower control unit Wiring Harness Connector (wiring harness side) Terminal A2 & Blower control unit Wiring Harness Connector (wiring harness side) Terminal A4 Connect fused jumper wire to: Blower control unit Wiring Harness Connector (wiring harness side) Terminal B1 & Blower control unit Wiring Harness Connector (wiring harness side) Terminal B5 Ignition ONBlower operates at maximum performance
Yes: E03No: E04
C-15, Blower Controller Command Circuit
ResultCause Of Fault
E01Defective component: U28 Adjustment Unit ASM - Electronic Climate Control or Blower control unit
E02Defective component: K6 Relay - Air Conditioning
E03Defective component: Blower control unit
E04Circuit interruption between: M10 Motor - Blower, Air Conditioning Wiring Harness Connector (wiring harness side) Terminal B & Blower control unit Wiring Harness Connector (wiring harness side) Terminal B1/A2 or M10 Motor - Blower, Air Conditioning Wiring Harness Connector (wiring harness side) Terminal A &
Blower control unit Wiring Harness Connector (wiring harness side) Terminal A4/B5 or Defective component: M10 Motor - Blower, Air Conditioning
E05Circuit interruption between: U28 Adjustment Unit ASM - Electronic Climate Control Wiring Harness Connector (wiring harness side) Terminal 17 (26P) & Blower control unit Wiring Harness Connector (wiring harness side) Terminal A1
E06Short circuit to ground between: U28 Adjustment Unit ASM - Electronic Climate Control Wiring Harness Connector (wiring harness side) Terminal 17 (26P) & Blower control unit Wiring Harness Connector (wiring harness side) Terminal A1
E07Short circuit to voltage/interruption of circuit between: M10 Motor - Blower, Air Conditioning Wiring Harness Connector (wiring harness side) Terminal B & Ground
E08Short circuit to ground/interruption of circuit between: M10 Motor - Blower, Air Conditioning Wiring Harness Connector (wiring harness side) Terminal A & K6 Relay - Air Conditioning Wiring Harness Connector (wiring harness side) Terminal 8 or Defective component: K6 Relay - Air Conditioning
E09Short circuit to voltage between: U28 Adjustment Unit ASM - Electronic Climate Control Wiring Harness Connector (wiring harness side) Terminal 17 (26P) & K6 Relay - Air Conditioning Wiring Harness Connector (wiring harness side) Terminal 8 or Defective component: K6 Relay - Air Conditioning