Technical Data
Cooling System
| Engine | 17 DT (TC 4 EE 1) | |||||||
|---|---|---|---|---|---|---|---|---|
| Radiator | ||||||||
| Type | Cross-flow | |||||||
| Radiator core surface | cm2 | 1900 | ||||||
| Coolant Filling Quantity | ||||||||
| Capacity of cooling system with heating in litres | 7.4 | |||||||
| Anti-freeze Mixture 2) | ||||||||
| When topping-up use Opel/Vauxhall Radiator Anti-freeze 19 40 656 (90 297 545). | ||||||||
| Required | to -10 °C | to -20 °C | to -30 °C | to -40 °C | ||||
| filling quantity | Quantity in litres | Quantity in litres | Quantity in litres | Quantity in litres | ||||
| (in litres) | Water | Anti-freeze | Water | Anti-freeze | Water | Anti-freeze | Water | Anti-freeze |
| (80%) | (20%) | (66%) | (34%) | (56%) | (44%) | (48%) | (52%) | |
| 7.4 | 5.9 | 1.5 | 4.9 | 2.5 | 4.1 | 3.3 | 3.5 | 3.9 |
1) The anti-freeze coverage ex works extends down to -30 °C
| Engine | 17 DT (TC 4 EE 1) | |
|---|---|---|
| Fan | ||
| Type | electric drive | |
| Number of blades | 5 | |
| Distribution of blades | assymmetric | |
| Diameter mm | 366 | |
| Thermo Switch | ||
| Stage I | Stage II | |
| Switches on at °C | 95 | 105 |
| Switches off at °C | 90 | 100 |
| Radiator Cap | ||
| Identification | 140 | |
| Opening pressure kPa (bar) | 140 to 150 (1.40 to 1.50) | |
| Thermostat | ||
| Type | Twin valve | |
| Main valve | Auxiliary valve | |
| Start of opening °C | 86 to 90 | 83 to 87 |
| Fully opened °C | 100 | 100 |
| Identification | 88 | 85 |