CDLS, Table 7, F7:PROGRAMMING
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 02 | PROGRAM KEY | This TECH 1 function can be used to program the infrared transmitters consecutively and individually into the central locking control unit. |
Ignition ON
Press key F7 in the TECH 1 main menu, select the desired test using the arrow keys and confirm with YES. Follow the instructions in the TECH 1 display.
Hold the infrared transmitter being programmed in the immediate vicinity of the infrared receiver and press the centre button several times.
Note:
With the ignition ON, the reception area of the infrared receiver is limited to a few centimetres.
| 14 |
|---|
| If the display on the right appears after programming, the relevant infrared transmitter has been successfully programmed. |
TECH 1 cannot automatically determine whether programming was successful. For this reason, carry out the following test steps:
· Switch ignition off/on
· Carry out test steps 14, 21, 22 and 25 to 34 from section F0:DATA LIST.
· Activate/deactivate the electronic immobiliser or the central locking using the two buttons of the reprogrammed infrared transmitter
| KEY PROGRAMMED! |
SEE CHECKING
PROCEDURE
| If the above display does not appear after programming, a fault is present. Carry out the following measures consecutively: |
· Check whether the corresponding LED illuminates when the buttons on the infrared transmitter are actuated.
(otherwise infrared transmitter batteries flat)
· Read out trouble codes.
· Carry out quick check F0:DATA LIST.
· Carry out quick check
F5:ACTUATOR TEST.
· Repeat programming.
· Carry out TECH 1 self-test.
· Check TECH 1 lead for damaged insulation and shielding.
· Repeat programming with new control unit.