Contents Wiring diagrams Section: Heating, Ventilation All sections

Torque Guide Values - All Vehicles Opel Combo C

Nm
Refrigerant lines to:
-Receiver-dryer5.5
– Expansion valve (TXV)7
-Compressor (all motor variants)20
Block connector compressor Z 17 DTH20
Bolt connection (separation point) for condenser20
Bolt connection (separation point) for refrigerant lines20
Pressure sensor on refrigerant line (up to model year 2003)7
Pressure sensor on receiver-dryer (as of Model Year 2004)11
Expansion valve (TXV) to evaporator5
Receiver-dryer bracket2
Condenser bracket to radiator5
Compressor bracket to engine Z 14 XE, Z 18 XE35
Compressor support to engine Z 16 SE35
Compressor bracket to engine Z 13 XE, Z 13 DTJ20
Main bracket compressor to motor Y 17 DTL, Y 17 DT, Z 17 DTH43
Engine cooling module bracket to body M 825
Engine cooling module bracket M 66
Lower radiator bracket to front axle body15