Home/Opel/Antara/Opel Antara I (2007-2011)/Repair manual/Cooling System/Draining and Refilling the Cooling System
Contents Wiring diagrams Section: Cooling System All sections

Draining and Refilling the Cooling System Opel Antara I

Cooling System 2 illustrations ~233 words



Draining and Refilling the Cooling System

Warning: Ensure the engine is cold when removing cap from the coolant fluid reservoir. Place a pan below the vehicle to catch the draining coolant.

  1. Remove the surge tank cap.
  2. Unplug the drain cock.

Warning: Observe the relevant environmental regulations when disposing of used coolant.

  1. Catch the escaping fluid in a drain pan.
  2. Remove all sludge and dirt from inside of the surge tank. Refer to Surge Tank Replace .
  3. Plug the drain cock.
  4. Add the clean water to the surge tank.
  5. Fill the tank slowly so that the upper reservoir hose remains above the water line. This allows the air inside the cooling system to escape.
  6. Start the engine.
  7. Run the engine until the thermostat opens. You can tell the thermostat is open when both radiator hoses are hot to the touch.
  1. Stop the engine.
  2. Repeat steps 1 through 9 until the drained water is clear and free of coolant and rust.

Important: Never use an antifreeze mixture more concentrated than 60% antifreeze to 40% water. The solution freezing point increases above this concentration.

  1. Fill the cooling system through the surge tank with a mixture of Dex–cool and water. The mixture must be at least 50% antifreeze, but not more than 60% antifreeze.
  2. Fill the surge tank to the specified MAX fill mark on the outside of the tank.