ONE OR MORE SWITCHES IN MASTER SWITCH ASSEMBLY INOPERATIVE
Note. If Nissan CONSULT scan tool not available, check power window main (master) switch status using on-board diagnostic mode II. For additional information see MULTIPLEX CONTROL SYSTEM article.
Check power and ground to BCM and LCU 01. See WIRING DIAGRAMS . Using Nissan CONSULT in DATA MONITOR mode, check status of switch in question while operating switch. If switch status is as expected, check multiplex communications. See MULTIPLEX CONTROL SYSTEM article. If switch status is not as expected, replace LCU 01.