INSPECTION AFTER INSTALLATION
- Check the engine oil level. Refer to " «ENGINE OIL : INSPECTION»(ref-382161-S26797745302011011400000) ".
- Start the engine and check for engine oil leakage.
- Stop the engine and wait for 10 minutes.
- Check the engine oil level and add engine oil as required.
Scheme 4
Scheme 4: SPARK PLUG : Removal and Installation
Scheme 5
- Disconnect the harness connector from the ignition coil.
- Remove ignition coil. CAUTION: Do not shock ignition coil.
- Remove spark plug using suitable tool.
Scheme 6
Scheme 6: INSPECTION AFTER REMOVAL
Scheme 7
- Do not use a wire brush for cleaning.
- If plug tip is covered with carbon, spark plug cleaner may be used. Cleaner air pressure: Less than 588 kPa (6 kg/cm2, 85 psi) Cleaning time: Less than 20 seconds
- Checking and adjusting plug gap is not required between change intervals.
TRANSFER FLUID : Inspection
| CAUTION | If using the vehicle for towing, the transfer fluid must be replaced as specified. Refer to FOR USA AND CANADA : Introduction of Periodic Maintenance " FOR MEXICO : Introduction of Periodic Maintenance ." |