HVAC - Overview: Adjustments MINI Cooper I

Mode 2: Calibration Run

The objective of the calibration procedure is to correct the position drift of the servomotors for temperature and air distribution control. During a calibration run

  1. Both servomotors are driven to their two end positions and the new values stored in the IHKA EEPROM.
  2. All LED's activated simultaneously.
  3. Blower streamer bars individually illuminated.
  4. CA flashes in the central display panel at 0.5 Hz.
CodeDescription
01Solar sensor fault
02Interior temperature sensor fault
03Heater core temperature sensor fault
04Air distribution servomotor feedback fault
05Blend flap servomotor feedback fault
06Blower switch minus fault
07Blower switch plus fault
08Interior sensor fan fault
09Air distribution servomotor fault
10Blend flap servomotor fault

IHKA FAULT CODES

There are three possible operating statuses shown in the central display

  1. CA = Calibration Active
  2. CC = Calibration Complete
  3. FF = Fault