ADJUSTMENT
HINT
- Use the same procedures for the LH side and RH side.
- The procedures listed below are for the RH side.
Scheme 69
- INSPECT QUARTER WINDOW ASSEMBLY RH Check that the clearance is within the standard value. (Scheme 69): Identifying Quarter Window Assembly RH Standard measurement AREA SPECIFIED CONDITION Area Specified Condition a 8.5 mm (0.335 in.) b 19.2 +-3.0 mm (0.756 +-0.118 in.) c 13.5 +-3.0 mm (0.531 in.) d 7.5 mm (0.295 in.) e 20.5 +-3.0 mm (0.807 +-0.118 in.) f 13.7 +-3.0 mm (0.539 +-0.118 in.) g 8.0 +-2.0 mm (0.315 +-0.079 in.)