Contents Section: Gauges & Instrument Panels All sections

Meter: Other Lexus RX II рестайлинг

FAIL-SAFE CHART

ENGINE COOLANT TEMPERATURE GAUGE

ConditionResponseRecovery
Engine coolant temperature data is interrupted for 5 seconds.The gauge needle indicates below "°C".Engine coolant temperature data is received.

ENGINE COOLANT TEMPERATURE GAUGE - FAIL-SAFE CHART

SHIFT INDICATOR

ConditionResponseRecovery
"P" to "D" data is interrupted for 3 seconds.All indicator light go off.Normal data is received.
"B" data is interrupted for 3 seconds.The "B" indicator light goes off.Normal data is received.

SHIFT INDICATOR - FAIL-SAFE CHART

ABS & BRAKE

ConditionResponseRecovery
ABS & brake data is interrupted for 3 seconds.The warning light comes on.Normal data is received.

ABS & BRAKE - FAIL-SAFE CHART

DOOR

ConditionResponseRecovery
Regular data is interrupted.The data received most recently remains indicated.Normal data is received.

DOOR - FAIL-SAFE CHART

POWER STEERING

ConditionResponseRecovery
P/S data is interrupted for 3 seconds..The indicator light comes on.Normal data is received.

POWER STEERING - FAIL-SAFE CHART

HEAD(*1)/TAIL (*2)

ConditionResponseRecovery
Regular data is interrupted.The data received most recently remains indicated.Normal data is received.

HEAD/TAIL - FAIL-SAFE CHART

BEAM

ConditionResponseRecovery
Regular data is interrupted.The indicator light goes off.Normal data is received.

BEAM - FAIL-SAFE CHART

AIRBAG

ConditionResponseRecovery
Airbag data is interrupted for 10 seconds or there is a malfunction in the combination meter (meter CPU).The warning light comes on.Normal data is received.

AIRBAG - FAIL-SAFE CHART

ILLUMINATION

ConditionResponseRecovery
The illumination data is interrupted for 10 seconds or abnormal data is received.The display remains in daytime mode.Normal data is received.

ILLUMINATION - FAIL-SAFE CHART

MULTI-INFORMATION DISPLAY

ConditionResponseRecovery
Cruise information data is interrupted for 60 seconds.The display becomes blank (only measurement units displayed).Normal data is received.
Energy flow data is interrupted for 2 seconds.The energy flow display becomes blank. (Cursor does not appear.)Normal data is received.
The battery data is interrupted for 2 seconds.The display before receiving the data is displayed.Normal data is received.
(1) U.S.A. (2) Except U.S.A.
(1)U.S.A.
(2)Except U.S.A.

MULTI-INFORMATION DISPLAY - FAIL-SAFE CHART