TRANSMISSION FLUID TEMPERATURE (TFT) SENSOR
Disconnect TFT sensor electrical connector. Using a DVOM, measure resistance between sensor terminals. Replace sensor if resistance is not within specification. See TFT SENSOR RESISTANCE table. TFT sensor is located on wiring harness in adapter case oil pan. (Схема №4)
| Temperature °F (°C) | Resistance (Ohms) |
|---|---|
| 40 (-40) | 672,000 |
| 32 (0) | 65,000 |
| 68 (20) | 25,000 |
| 176 (80) | 2,500 |
| 248 (120) | 780 |
| 302 (150) | 370 |
TFT SENSOR RESISTANCE